Ada regulations also state that baby changing stations must be located in an area that is easily accessible and free from obstructions.
Baby changing station mounting height ada.
Five tips for ada compliance.
Install at the perfect height.
The ada requires 59 inches and 27 inches your manufacturer s instruction sheet should be consulted for recommended mounting heights.
Figure 308 2 a forward reach.
Any change to restroom functionality inevitably turns to the question of americans with disabilities act ada compliance.
Complete the design by providing the required amount of toe clearance underneath the lavatory of 17 inches 430mm to 25 inches 635mm maximum.
Baby changing stations types.
Where a forward reach in unobstructed the high forward reach shall be 48 inches 1220 mm maximum and the low forward reach shall be 15 inches 380 mm minimum above the finish floor or ground.
See figure s 308 2 a.
Recess mounted stainless steel clad baby changing station is the premier choice for upscale restroom facilities.
Horizontal stainless steel recess mounted kb110 ssre.
Below is a diagram from diaper depot about mounting baby changing stations.
The ada mandates that baby changing stations be present in both men s and women s restrooms and must be placed at a height of 27 inches from the floor.
The ada americans with disabilities act has set requirements for baby changing stations.
Knee clearance must extend 25 inches under a changing table and the unit must be 9 inches above the finish of the ground.
Protruding objects units are not to protrude more than 4 inches from the wall when closed.
Toe clearance at least 9 inches 230mm above the finish floor must be provided for the full depth.
Listed below are standards for baby changing stations.
The americans with disabilities act ada was created to ensure access to buildings and structures for people with disabilities.
Check your local code for addition information and requirements.
There are specific mounting heights and other requirements of baby changing stations in restrooms says ada compliance expert joan stein of stein consulting inc pittsburgh.
This is required so patrons using wheelchairs can easily access the unit as well as open and close the changing station.
For horizontal changing stations the ada requires that the unit protrude no more than 4 from the wall and be no higher than 27 inches from the floor.